Therefore, differential protection of transformer should be provided with a proportional bias of an amount which exceeds in effect the maximum ratio deviation. Current transformers in a differential scheme must be chosen to have nearidentical response to high overcurrents. Pdf transformer differential protection is exposed to faulty operation related to abnormal operation. This is generally expressed as a percentage of the rms value of the primary current. Thus this scheme provides protection to the greater percentage of the stator winding. In addition, interposing cts may be used to reduce the effective lead burden of long secondary leads. In new merged file both signals start at the same moment, as presented in figure 4. Differential protection of transformer differential. Differential protection of generator or alternator electrical4u. Principles of differential relaying the restraint characteristic suppose further that there is 0. Comparing current flowing into a line to the current flowing out of the same line allows for a simple protection scheme. Merz price differential protection scheme gate ee power. The optional sel2664 field ground module accurately detects field ground faults whether the generator is operating, stopped, or deenergized.
In this type of protection the electrical quantities entering and leaving the protected zone or area are compared by current transformers c. Zerosequence current differential protection for high impedance earth faults zerosequence current differential protection can detect high impedance earth faults even with heavy load current. The percentage restraint characteristic requires that the differential current be greater than a percentage of the through restraint current. The slope characteristic provides high sensitivity. Line differential protection modeling with co mposite current and volt age hamzah eteruddin 61 the relay commanded the breaker to trip at an equal period of time i. Differential protection of transformer differential relays.
May 15, 2018 generally differential protection is provided in the electrical power transformer rated more than 5mva. It is also possible to combine the traditional percentage differential scheme with. L to limit current through relay to percentage differential protection scheme forms the basis of the practically very commonly used percentage differential protection scheme for alternator stator windings. The mathematical relationship between differential protection and directional protection is derived. The slope characteristic provides high sensitivity when low levels of current. In this video, ankit goyal cofounder at kreatryx and air 1 in gate 2014 describes the merz price differential protection scheme for. Mohammed tawfeeq alzuhairi 321 differential protection differential protection is the best technique in protection. Transformer differential protection percentage restraint differential protective relays have. With the differential protection relaying, the cts at both end of the stator windings must be same. Before joining beckwith electric, performed in application, sales and marketing. Protection relays differential relays b high impedance differential protection. The faults occur in the transformer inside the insulating oil can be detected by buchholz relay. Generator stator protection, underover voltage, under over.
Scope this document introduces the application of the threephase differential protection in ref542plus. Micro processor based advanced bus protection scheme using. The differential protection of transformer has many advantages over other schemes of protection. The differential protection of power transformer is a unit protection scheme. Sv data loss on line percentage differential, alpha plane differential, and line. Quite a number of protection systems have been designed for busbars. Percentage differential protection for transformers the percentage differential protection or merzprice protection based on the circulating current principle can also be used for the transformers. For power transformers, it is recommended that percentage differential protection be provided for transformers rated kva and above if circuit breakers are provided for each winding into which power can flow when an internal fault occurs, and for all.
Line differential protection modeling with co mposite current and volt age hamzah eteruddin 61 the relay commanded the breaker to trip at an equal period of. For alternator the most severe out come of fault is the damage of stator. The percentage differential relay is defined as the relay that operates on the phase difference of two or more similar electrical quantities exceeds a predetermined amount. It is the advanced form of differential protection relay. Protection and testing considerations for iec 61850 sampled. Pdf a new transformer differential protection approach on the. Through fault means a fault outside the zone of protection. Differential protection of yy and connected power transformer mayurdhvajsinh p. Differential protection or merzprice circulating current. Differential protection can be used to provide protection for zones with multiple terminals and can be used to protect lines, generators, motors, transformers, and other electrical plant. Directional blocking protection of these, 1 is suitable for small substations only, while 4 and 5 have become obsolete. The highimpedance input is created by an internal impedance, typically resistive, of 2000 ohms or higher. There are several methods available for the protection of transmission and distribution lines 69. The differential relay works on the principle of comparison between the phase angle and magnitude of two or more similar electrical quantities.
It applies the percentage ratio differential characteristic shown in figure 2. Scribd is the worlds largest social reading and publishing site. Problems for the differential protection caused by transformer inrush currents are discussed. Multipurpose percentage restraint differential protection radsc 1mrk 509 016ben page 2 application contd interposing cts are used to balance the main ct ratios when necessary. Percentage restrained differential, percentage of what. Commissioning a test for a differential protection scheme for. Percentage differential type ijd relays introduction inter. The percentage differential protection or merzprice protection based on the circulating current pronciple can also be used for the transformers.
Multipurpose percentage radsc restraint differential protection. Commissioning a test for a differential protection scheme for a threewinding transformer figure 1. For generator differential protection, one set of current transformers ct are located on generator neutral side, whereas second set of ct is located on generator phase side. Aug 30, 2018 any internal fault inside the stator winding is cleared by mainly differential protection scheme of the generator or alternator. Sep 08, 2016 general scheme of differential protection 6. Abstractline current differential protection creates challenges for relay design and application. Transformer differential protection must deal with fictitious differential signals caused by magnetizing inrush conditions while striving for fast operation and sensitivity to turntoturn faults, for example. Procedure to do differential calculation for transformer protection relay slideshare uses cookies to improve functionality and performance, and to provide you with relevant advertising. In the event of such faults, the quick response of the differential element may limit the damage that may have otherwise occurred to the motor. Percentage differential protection for transformers your. Iid52a 1 generators 21 5 iid52b 3 generators 22 6 iid53c 1 transformers 21 16 iid53d 3 transformers 22 17 the type lid relays comprise a group that is used for differential protection of alternating cur.
Preparation of reval files from two line differential protection terminals rel 561 or rel 551 for. Selecting transformer compensation settings for secure differential. The differential protection is designed to protect power transformers or highvoltage motors. Misoperation cases on transformer differential protection.
A new approach to current differential protection for transmission. Thompson, schweitzer engineering laboratories, inc. In a percentage restraint current differential relay, the oper ating current is the. Differential protection for arbitrary 3ph power transformer. A sensitive current element in series with the highimpedance element is calibrated in volts based on the voltage drop across the internal impedance. Percentage differential protection slope in differential. Apr 28, 2018 as discussed in the post transformer differential protection, differential protection is supposed to operate for the internal faults or for the zone of protection it is intended for. Preparation of reval files from two line differential. In a percentagerestrained differential relay, cts from both sides of the protected. Modern line current differential protection solutions. Differential protection of alternator or merzprice circulating current protection system is a only protection system that protects alternator stator from burning through at least 80% of it. Mr lee wai meng shares some of his experience in the protection of transformers, through a case study. A differential protection relay is defined as the relay that operates when the phase difference of two or more identical electrical quantities exceeds a predetermined amount.
Differential relays provide highspeed 1 to 2 cycles, sensitive, and inherently selective protection. In merge window enter the measured time difference 4ms in our case into the skew window and press ok. Fuses are single phase protective devices that combine sensing and interrupting. Differential protection may be considered the first line of protection for internal phase to phase or phase to ground faults.
At maximum through fault current, the spill output produced by the small percentage unbalance may be substantial. Unit protection apply sensitive percentage restrained current differential. Pdf line differential protection modeling with composite. The percentage biased differential relay comprises two restraint coils and one operating coil per phase.
Percentage restrained differential relays measure the individual branch currents and quantify the through current in the zone of protection. Pdf this paper discusses the protection system which is the most important part in a. Nov 01, 2016 a differential relay is defined as the relay that operates when the phase difference of two or more identical electrical quantities exceeds a predetermined amount. Jan 14, 2017 a differential relay is defined as the relay that operates when the phase difference of two or more identical electrical quantities exceeds a predetermined amount. Th e transformer is one of the most important items of hardware in the electrical power system. In order to avoid the problem of maloperaration of relays due to ct saturation and transient dc current, biased differential protection scheme is used. Most 87t relays would use the percentage characteristic to.
Current differential line protection setting consideration. This system gives protection against phase to phase faults and phase to ground faults to the power transformers. Principles of differential relaying my protection guide. Current differential line protection current differential relaying is a method of extending the benefits of differential protection as applied to transformers, buses or generators to the protection of transmission lines. These will not provide protection for turntoturn winding faults in generators, motors, and transformers because of the small increment in the current produced by such faults, which remain below the pickup sensitivity of the relays. The differential zone of the relay can include up to. Each type of differential protection faces its own unique challenges. Modern line current differential protection solutions hank miller and john burger, american electric power normann fischer and bogdan kasztenny, schweitzer engineering laboratories, inc. The differential protection is provided in the generator by using longitudinal differential relay. This popular scheme is known as biased differential protection or merzprice protection. Protection functions bias differential protection 87 harmonic restraint protection over fluxing i. This paper carries the idea of selection of dual slope differential relay parameters for various faulty conditions on the system. Line current differential protection is no exception.
What is merz price protection percentage differential. The only difference between them is the restraining coil. Abstractpercentage restrained differential protection is one of the oldest forms of adaptive protection algorithms. Differential protection is not supposed to operate for a through fault. Pdf line differential protection modeling with composite current.